Catalogue values for Electronic Weigh Bridge (Without Civil Work)

Category Specification Bid Requirement (Allowed Values)
Performance Parameters Providing Required test load Yes, No(Seller not providing and buyer to arrange same)
The test load requirements Provided 500 kg, 1 ton, 2 ton, 3, 5, 10, NA(in case seller not providing)
Type of Weigh Bridge Surface Mounted, Pit Mounted, Portable (Movable)
Maximum Capacity of weigh Bridge in Tonnes 20, 30, 40, 50, 5, 60, 80, 100, 120, 10
Graduation of weigh bridge in KG 1, 2, 5, 10, 20, 50
Warranty Period in Years 1, 2, 3, 4, 5
CONSTRUCTION FEATURES The type of Construction of Weigh Bridge Plat form Modular enabling easy Assembly ,Transportation and adjustment of Size, Fully welded structure
Length of the Platform required for weighing in meters 7.5 m, 9m, 12m, 16m, 20 m, 18m, 24 m, 4.5
Width of the Plat form in meters 3m, 4 m, 4.5m
Ramp length in mm 1:10 for portable for 1 feet height 10 feet length, NA ( For surface Mounted and Pit mounted)
load Cell Capacity of Load Cell in Tonnes 10 ton, 20 Ton, 30Ton, 40 Ton
No of Load Cell in the weigh bridge system 4, 6, 8, 10, 12
Type of Load Cell Compression Type, Double ended Shear Beam Load Cell
Load cell technology Analog, Digital
Material of Body of Load Cell Stainless Steel, Nickel plated Alloy steel
Protection class for load cell IP 65, IP67, IP 68
Certification required for for load cell RRSL, OIML
Auto rotation lock yes for compression type load cell, NA( For double endede shear beam load cell )
LENGTH of cable Provided for load cell in meters 6, 9, 12
shall be provided with automatic diagnostics Yes, No
shall be unaffected by off center loads Yes, No
Rated ouput Repeatability in terms of FS 0.05%, 0.01%
Overload rating SAFE 125%, 150%
Weigh Bridge Controller Housing Protection for Digital Controller IP 40, IP 60, IP 65
Details of Printer type dot matrix 80 col, laser printer
Printer Make epson, tvse
USB port provided Yes, No
No of digits of led display for weight 6, 8
Minimum character size of LCD Display 16x2, 32x2, 40x2
Provision for remote Display port Yes, No
Protection class for junction box for connection IP 65, IP 66, IP 67, IP 68
Surge protection for junction box Yes, No
Material of construction for junction box ABS, MILD STEEL, STAINLESS STEEL
Back up time in hours 2, 4, 6, NA if UPS not provided
Additional parameters Number of additional load cell to be supplied 1, 2, 3, Not supplied
UPS to be provided with the system Yes, No