Catalogue values for Polygraph System (Forensic Lie Detector)
Category | Specification | Bid Requirement (Allowed Values) |
---|---|---|
DATA ACQUISITION SYSTEM | No of Channels for simultaneous recording | 5, 6, 7, 8, 9, 10, 4, 12, 16, 24, 32 Or higher |
Resolution (Analog to Digital Conversion) | 24, 32, 16 Or higher | |
PROBES / SENSORS | "No of Pneumo Chest Assembly sets supplied (inclusive in the scope of supply) (each set consists of Thoracic & Abdominal assembly) " | 1, 2, 0 |
"No of Electro Dermal Response Sensor sets supplied (inclusive in the scope of supply) (each set consists of 2 Sensor electrodes)" | 1, 2, 0 | |
No of Cardio Pump and Gauge Assembly (Sphygmamanometer) supplied (inclusive in the scope of supply) | 1, 2, 0 | |
No of Adjustable Blood pressure cuffs supplied (inclusive in the scope of supply) | 1 Cuff (Adult Size-Medium), "1 Cuff (Adult Size-Medium) + 1 Cuff (Adult Size-Large)", "1 Cuff (Adult Size) + 1 Cuff (Adult Size-Large) + 1 Cuff (Child Size)", 0, 1, 2 | |
No of PPG Clips supplied (inclusive in the scope of supply) | 1, 2, 0 | |
POLYGRAPH SOFTWARE | Type of Licence of Polygraph Software | Perpetual License with free updates during warranty period |
Scoring Type | Computerized measurements; Object Scoring System (OSS) Algorithms; Emperical Scoring System (ESS) Algorithms; Plethysmograph (PLE) vasomotor measurements; Chart Stacker for global scoring; Relative Response Magnitude graphs; Pulse Amplitude graphs; Pharmaceutical dug reference library; Respiration (Thoracic & Abdominal Respiration) measurements; Measurement of Blood pressure & Blood Volume Changes; Galvanic Reflex measurements at the Finger Tips; Customizable report templates:, Manual Only (1) Or higher | |
"Software Features (Select only applicable Parameters)" | Computerized measurements, Object Scoring System (OSS) Algorithms, Emperical Scoring System (ESS) Algorithms, Plethysmograph (PLE) vasomotor measurements, Chart Stacker for global scoring, Relative Response Magnitude graphs, Pulse Amplitude graphs, Pharmaceutical dug reference library, Respiration (Thoracic & Abdominal Respiration) measurements, Measurement of Blood pressure & Blood Volume Changes, Customizable report templates: | |
SALIENT FEATURES | "Salient Features (Select only applicable Parameters)" | Customizable question Template, Real Time Recording with Event Marker, Adjustable Question Timing Facility |
Minimum requirements of the sytem hardware/Software for satisfactory operation of Polygraph system (PC / Laptop is not included in the scope of supply) | "Supported Operating System Software Version (Not included in the scope of supply)" | Windows 7, 32-bit, Windows 10, 32-bit, Windows 7, 64-bit, Windows 10, 64-bit |
ACCESSORIES | Compatible Fingerprint Scanner inclusive in the scope of supply | Yes, No |
Supply of suitable Adjustable arm subject's Chair for Polgraph test inclusive in the scope of supply | Yes, No | |
Type Chair for Polgraph test | Adjustable arm subject's Chair with folding mechanism (portable), Adjustable arm subject's Chair without folding mechanism, NA | |
Carrying case for Polygraph System | Yes, No | |
Material of carrying case supplied | Leather, Leatherite, ABS, Polycarbonate, Poly Propylene, Nylon, NA | |
WARRANTY / SUPPORT / SERVICES | Warranty on Data Acquisition System | 2, 3, 5, 1, 4 |
Warranty on Probes / Sensors | 2, 3, 5, 0, 1 | |
No of days Training Provided | 3, 5, 7, 1, 2, 4, 6 | |