Catalogue values for Online UPS (V2)
Category | Specification | Bid Requirement (Allowed Values) |
---|---|---|
Generic | Rating in KVA | 1.0 KVA, 2.0 KVA, 3.0 KVA, 5.0 KVA, 6.0 KVA, 7.5 KVA, 10.0 KVA, 15.0 KVA, 20.0 KVA, 25.0 KVA, 30.0 KVA, 40.0 KVA, 50.0 KVA, 60.0 KVA, 80.0 KVA, 100.0 KVA, 120 KVA, 160 KVA, 200 KVA, 300.0 KVA, 500.0 KVA, 800.0 KVA, 250.0 KVA |
Switching Technology | IGBT-PWM | |
Input Voltage | AC Single phase 160V - 260V 50Hz, AC Three phase 300 V - 450V sinewave 50Hz | |
Output Voltage | AC Single phase 230V +/-1% 50 Hz, AC 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz, AC 3 phase 415V having a variable setting the range starting from 380 volt - variable upto to 415 volt. | |
Warranty for UPS (Years) | 1, 2, 3, 4, 5 Or higher | |
Battery/Backup Bank | Battery/Backup Bank Provided with Online UPS ( Hint: In case the UPS is supplied with battery, seller shall ensure compliance to the GST Rates as per recommendations made in the 45th Meeting of GST council dated 17th Sep 2021 ) | With Battery, Without Battery |
Type of Battery (hint: NA in case Battery not provided) | SMF-VRLA conforming to JISC:8702(Pt.I,II&III), Stationary Lead Acid Batteries (with tubular positive plates) in monobloc container conforming to IS:13369:1992 latest, Stationary Cells and Batteries, Lead Acid type (with tubular positive plates) conforming to IS:1651:1991 latest, NA, Lithium Ion Battery [ as per IS 16046 (part 2)/ IEC 62133-2 and as per IEC 62485-5] | |
Backup time (Minutes) (hint: NA in case battery not provided) | 15 Minutes, 30 Minutes, 60 Minutes, 90 Minutes, 120 Minutes, 180 Minutes, 240 Minutes, NA | |
Warranty for battery (Years) by Battery Manufucaturer/Brand hint: NA in case battery not provided | 1, 2, 3, NA Or higher | |
Performance / Functional | Inbuilt isolation transformer | With, Without |
Overall Efficiency (%) | >/=80% & <90% with Inbuilt isolation transformer, >/=90% with Inbuilt isolation transformer, >/=90% & <94% without Inbuilt isolation transformer, >/=94% without Inbuilt isolation transformer | |
Overload limit | 20% Overload for minimum 10 minute, 20% Overload for minimum 5 minute, 50% Overload for minimum 1 minute, 50% Overload for minimum 3 seconds | |
Accessories | Accessories | Rack for Batteries, Cabling 6 meters ( input upto 3m and output upto 3m), Paralleling kit (Hot Standby Configuration), Paralleling kit for synchronizing (Parallel Redundant Load Sharing Configuration), SNMP Card ( with Suitable Software ) for communication, The UPS shall be complete with Trolley for battery bank,battery, Cables and connectors etc, NA |
Design / Construction | Type of Design / Construction | Floor Standing, Rack Mountable |