Catalogue values for Sit Up Board - Outdoor Gym Equipment
Category | Specification | Bid Requirement (Allowed Values) |
---|---|---|
TYPE | Type | Single Station, Double Station |
MATERIAL | Type of Back Rest | Perforated Sheet, Set of Rectangular Flat Pipes, Plain Sheet |
Material of Back Rest | Fibre Reinforced Plastic, Mild Steel Plate, LDPE, HDPE, Galvanized Iron(GI) | |
Governing Specification for GI Pipes | BIS specification No IS 1239 ( Part 1 )- 2004, latest, BIS specification No IS 1161:2014, latest | |
All the GI Pipes are ISI marked | Yes, No | |
Main Frame/Central Pipe | 50mm Nominal Bore G.I. Pipe, 80mm Nominal Bore G.I. Pipe, 100 mm Nominal Bore G.I. Pipe, 125mm Nominal Bore G.I. Pipe, 150mm Nominal Bore G.I. Pipe | |
Main Frame/Central Pipe, Class as per IS 1239 | Medium, Heavy, Not applicable for pipe as per IS 1161 | |
Main Frame/Central Pipe ( As per Clause 3, of IS 1161 ) Nominal Bore & Wall Thickness | 80 mm NB with 3.2 mm Thickness, 80 mm NB with 4 mm Thickness, 80 mm NB with 4.8 mm Thickness, 100 mm NB with 3.6 mm Thickness, 100 mm NB with 4.5 mm Thickness, 100 mm NB with 5.4 mm Thickness, 125 mm NB with 4.5 mm Thickness, 125mm NB with 4.8 mm Thickness, 125 mm NB with 5.4 mm Thickness, 150 mm NB,165.1 mm OD & 4.5 mm Thickness, 150 mm NB,165.1 mm OD & 4.8 mm Thickness, 150 mm NB,165.1 mm OD & 5.4 mm Thickness, 150 mm NB,165.1 mm OD & 5.9 mm Thickness, 150 mm NB,165.1 mm OD & 6.3 mm Thickness, 150 mm NB,165.1 mm OD & 8 mm Thickness, 150 mm NB,168.3 mm OD & 4.5 mm Thickness, 150 mm NB,168.3 mm OD & 4.8 mm Thickness, 150 mm NB,168.3 mm OD & 5.4 mm Thickness, 150 mm NB,168.3 mm OD & 6.3 mm Thickness, 150 mm NB,168.3 mm OD & 8 mm Thickness, 150 mm NB,168.3 mm OD & 10 mm Thickness, 50 mm NB with 2.9mm Thickness, 50 mm NB with 3.6mm Thickness, 50 mm NB with 4.5 mm Thickness, Not Applicable | |
Grade of Material as per table 2 of IS 1161 | YSt 210, YSt 240, YSt 310, YSt 355, Not Applicable | |
Foot Rest Pipe | 32mm Nominal Bore G.I. Pipe, 40mm Nominal Bore G.I. Pipe, 50mm Nominal Bore G.I. Pipe | |
Foot Rest Pipe , Class as per IS 1239 | Medium, Heavy, Not applicable for pipe as per IS 1161 | |
Foot Rest Pipe ( As per as per Clause 3, of IS 1161 ) , Nominal Bore & Wall Thickness | 32 mm NB with 2.6 mm Thickness, 32 mm NB with 3.2 mm Thickness, 32 mm NB with 4 mm Thickness, 40 mm NB with 2.9 mm Thickness, 40 mm NB with 3.2 mm Thickness, 40 mm NB with 4 mm Thickness, 50 mm NB with 2.9 mm Thickness, 50 mm NB with 3.6 mm Thickness, 50 mm NB with 4.5 mm Thickness, Not Applicable | |
Grade of Material as per table 2 IS 1161 | YSt 210, YSt 240, YSt 310, YSt 355, Not Applicable | |
Back Rest Frame Pipe and Connecting Links | 25 mm Nominal Bore G.I. Pipe, 32 mm Nominal Bore G.I. Pipe, 40 mm Nominal Bore G.I. Pipe | |
Back Rest Frame Pipe and Connecting Links, Class as per IS 1239 | Medium, Heavy, Not applicable for M.S. Plates and Pipes as per IS 1161 | |
Back Rest Frame Pipe and Connecting Links ( As per Clause 3, of IS 1161 ) Nominal Wall & Thickness | 25 mm NB with 2.6 mm Thickness, 25 mm NB with 3.2 mm Thickness, 25 mm NB with 4 mm Thickness, 32 mm NB with 2.6 mm Thickness, 32 mm NB with 3.2 mm Thickness, 32 mm NB with 4 mm Thickness, 40 mm NB with 2.9 mm Thickness, 40 mm NB with 3.2 mm Thickness, 40 mm NB with 4 mm Thickness, Not Applicable | |
Grade of Material (as per table 2 of IS 1161 ) | YSt 210, YSt 240, YSt 310, YSt 355, Not Applicable | |
Leg Support Pipe | 32mm Nominal bore G.I. pipe, 40 mm Nominal bore G.I. pipe, 50mm Nominal bore G.I. pipe | |
Leg Support Pipe , Class as per IS 1239 | Medium, Heavy, Not applicable for pipe as per IS 1161 | |
Leg Support Pipe ( as per IS 1161 ) as per clause 3, Nominal Wall & Thickness | 32 mm NB with 2.6 mm Thickness, 32 mm NB with 3.2 mm Thickness, 32 mm NB with 4 mm Thickness, 40 mm NB with 2.9 mm Thickness, 40 mm NB with 3.2mm Thickness, 40 mm NB with 4 mm Thickness, 50 mm NB with 2.9 mm Thickness, 50 mm NB with 3.6mm Thickness, 50 mm NB with 4.5mm Thickness, Not Applicable | |
Grade of Material per table 2 of IS 1161 | YSt 210, YSt 240, YSt 310, YSt 355, Not Applicable | |
Foundation Pipes with anchoring | 750mm deep GI Pipe, supported with M.S. Angle 25 X 25 X 4mm, 500mm deep GI Pipe, supported with M.S. Angle 25 X 25 X 4mm | |
Nominal Bore of Foundation Pipe | 80mm, 100mm, 125mm, 150mm | |
Foundation Pipe, Class as per IS 1239 | Medium, Heavy, Not applicable for pipe as per IS 1161 | |
Foundation Pipe Pipe ( as per IS 1161 ) as per clause 3, Nominal Wall & Thickness | 80 mm NB with 3.2 mm Thickness, 80 mm NB with 4 mm Thickness, 80 mm NB with 4.8 mm Thickness, 100 mm NB with 3.6 mm Thickness, 100 mm NB with 4.5 mm Thickness, 100 mm NB with 5.4 mm Thickness, 125 mm NB with 4.5 mm Thickness, 125mm NB with 4.8 mm Thickness, 125 mm NB with 5.4 mm Thickness, 150 mm NB,165.1 mm OD & 4.5 mm Thickness, 150 mm NB,165.1 mm OD & 4.8 mm Thickness, 150 mm NB,165.1 mm OD & 5.4 mm Thickness, 150 mm NB,165.1 mm OD & 5.9 mm Thickness, 150 mm NB,165.1 mm OD & 6.3 mm Thickness, 150 mm NB,165.1 mm OD & 8 mm Thickness, 150 mm NB,168.3 mm OD & 4.5 mm Thickness, 150 mm NB,168.3 mm OD & 4.8 mm Thickness, 150 mm NB,168.3 mm OD & 5.4 mm Thickness, 150 mm NB,168.3 mm OD & 6.3 mm Thickness, 150 mm NB,168.3 mm OD & 8 mm Thickness, 150 mm NB,168.3 mm OD & 10 mm Thickness, Not Applicable | |
Grade of Material (as per table 2 of IS 1161) | YSt 210, YSt 240, YSt 310, YSt 355, Not Applicable | |
M S Foundation Plate Thickness | 10, 12 | |
OTHER REQUIREMENTS | Installation | Included, Not Included |
CERTIFICATION | Certfication ( Safety and Quality Requirements ) | As per European Standard EN 16630, No |
WARRANTY | Warranty ( years ) | 2, 3, 4, 5 |