Catalogue values for Neonatal Ventilator
Category | Specification | Bid Requirement (Allowed Values) |
---|---|---|
Performance Parameters | Patient Type | Neonatal, Premature |
Tidal Volume Range In ml | 2-300, 2-700 | |
Trigger Sensitivity Mechanism | Pressure, Flow, Pressure and Flow | |
Flow Pattern/Waveform Adjustment | Yes, No | |
IE Ratio range | 1:1 to 4:1, 1:10 to 4:1, 1:19 to 4:1, 1:6 to 3:1 | |
Sigh Breath Function | Yes, No | |
Leak Compensation Available | Yes, No | |
Auto 100% increase O2 Button | Yes, No | |
Inspiratory Pause Available | Yes, No | |
Expiratory Hold Available | Yes, No | |
Suction Control Option Available | Yes, No | |
Nasal CPAP Option Available | Yes, No | |
Auto PEEP Manoeuvre | Yes, No | |
Control Panel Lock | Yes, No | |
Facility for double lung ventilation | Yes, No | |
Ventilation Modes | CMV (Controlled Mandatory Ventilation) | Yes, No |
Assisted/Controlled Ventilation | Yes, No | |
PSV(Pressure supported ventilation) | Yes, No | |
SIMV(Synchronized Intermittent Mandatory Ventilation) | Yes, No | |
CPAP(Continuous Positive Airway Pressure Ventilation) | Yes, No | |
Pressure Controlled 3 Selectable inspiratory pressure | Rectangle, Half-sine, Linear | |
P-CMV(Inspiration pressure control) | Yes, No | |
P-CMV With Expiratory Minimal volume | Yes, No | |
P-CMV with minimum pressure | Yes, No | |
SIMV(Synchronized intermittent Mandatory Ventilation) with PCMV | Yes, No | |
ITT - Inspiratory Time Termination | Yes, No | |
CPAP:Continuos Positive Airway pressure Ventilation CPAP With backup Ventilation | Yes, No | |
P-CMV with Exp Volume control Available | Yes, No | |
High Frequency Oscillation Ventilator(HFOV) | Yes, No | |
High Frequency Oscillations | Frequency | 5-15, 3-15, 5-20 |
Amplitude | 0-100, > 90 | |
PATIENT ASSESSMENT TOOLS | Maximum Waveform Displayed | 2, 3, 4 |
Maximum Trending Time | ≥ 24, ≥48, ≥72 | |
Lung recruitment tools(PV loops) | Yes, No | |
Stress Index | Yes, No | |
Lung Mechanics Visualization Tool | Yes, No | |
Capnography/Co2 Monitoring | Yes, No | |
Volume Guarantee | Yes, No | |
APRV | Yes, No | |
Oxygen Therapy | Yes, No | |
Esophageal/Transpulmonary pressure Monitoring | Yes, No | |
INTEGRATED CAPABILITIES | Integrated Nebulizer | Yes, No |
ETCO2 Inbuilt available | Yes, No | |
Heliox Compatibility | Yes, No | |
Humidifier | Yes, No | |
Monitored or Displayed | Peak Inspiratory Pressure Monitored | Yes, No |
Mean Airway Pressure | Yes, No | |
PEEP Pressure | Yes, No | |
Tidal Volume | Yes, No | |
Minute Volume | Yes, No | |
Spontaneous Minute Volume | Yes, No | |
FiO2 Monitored | Yes, No | |
Display Respiratory rate | Yes, No | |
Display Inspiratory Time | Yes, No | |
Display Expiratory Time | Yes, No | |
Display I:E Ratio | Yes, No | |
Alarms | Low/High Fio2 Alarm | Yes, No |
Low Minute Volume Alarms | Yes, No | |
High Minute Volume | Yes, No | |
Low Inspiratory Pressure Alarm | Yes, No | |
High Pressure Alarm | Yes, No | |
Loss of PEEP Alarm | Yes, No | |
Apnea | Yes, No | |
Continuous High pressure/Occlusion Alarm | Yes, No | |
Inverse I:E Ratio Alarm | Yes, No | |
High Respiratory Rate Alarm | Yes, No | |
High PEEP Alarm | Yes, No | |
Breathing Circuit Disconnect Alarm | Yes, No | |
Gas Supply Failure Alarm | Yes, No | |
Power Failure Alarm | Yes, No | |
Low Battery Alarm | Yes, No | |
Humdifier | Disposable Neonatal breathing circuit | 50, 100, 150 |
Water trap in expiratory limb available | Yes, No | |
Auto Feed Humidification chamber Available | Yes, No | |
Additional Parameters | Output Ports Type | RS-232, Ethernet, RJ 45, USB |
Remote Alarm Display Port | Yes, No | |
Reporting (Vent alarms and Patient Status) | Yes, No | |
View Reports on Display | Yes, No | |
Save Data to USB | Yes, No | |
Send Data Via Network | Yes, No | |
Display Type | COLOR LCD With touchscreen, Dimmable color touchscreen ,TFT, Dimmable color Capacitive touchscreen,TFT | |
Display Size in Inches | ≥ 5, ≥ 10, ≥ 15, ≥ 20 | |
Can be used For Patient Transport | Yes, No | |
In Built Air Compressor/Turbine | Yes, No | |
Accessories | Number of nenontal Reusable silicon breathing circuits | 1, 2, 3 |
Non-invasive masks | Yes, No | |
Type of Flow Sensor | Reuasble, Disposable | |
No of Disposable flow sensor | 20, 50, 100, NA if Reusable | |
Trolley with ventillator with supporting arm from same manufacturer | Yes, No | |
Autoclavable exhalation valve/expiratory cassette | 2, 3 | |
Test Lung Available | Yes, No | |
Power Requirements | Type of battery | Lithium-ion ,, Ni-MH, Lead acid |
Operating time of battery in min | 60, 120, 180 | |
Miscellaneous Parameters | Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3, 4, 5, 1, 2 |