Catalogue values for Hyper Converged Infrastructure for Data Center (V2)
Category | Specification | Bid Requirement (Allowed Values) |
---|---|---|
BASIC INFORMATION | Type of HCI offered | 3. Generic node HCI(consisting both Compute and Storage) |
Total usable Cores available (after installation of HCI software resources required for solution) in the offered solution (Hint :- Select '0' if not applicable) | 140.0 - 3000.0 Or higher | |
Total usable Storage in TB available without using De-duplication,Compression (after installation of HCI software resources required for solution) in the offered solution (Hint :- Select '0' if not applicable) | 110.0 - 1000.0 Or higher | |
Total usable RAM in GB available (after installation of HCI software resources required for solution) in the offered solution (Hint :- Select '0' if not applicable) | 3248.0 - 12000.0 Or higher | |
Types of data copies across Cluster available in the offered solution (Hint: Select 0 if not aaplicable) | 2 | |
Number of Nodes offered in HCI Cluster (Hint:- 1 node option upgrade or DR only) | 7 | |
Number of Sockets offered per Node | 2 | |
Number of Cores per Sockets | 12.0 - 40.0 Or higher | |
Number of populated Processor per Node | 2 | |
Type of Processor offered in the system | 1. Intel Skylake, 2. Intel Cascade lake, 3. Intel latest processor, 4. AMD EPYC Processor | |
Type of storage media offered with the solution | 1. SSD Drives, 2.SAS Drives | |
Total Storage capacity (RAW) offered per node in TB (Hint: - 0 is only for compute node) | 39.68 - 1000.0 Or higher | |
Storage capacity offered per node with SAS drives in TB (Hint :- Select '0' if not applicable) | 32.0 - 1000.0 Or higher | |
Storage Scalability per node with SAS drives in TB (Hint :- Select '0' if not applicable) | 0.0 - 8000.0 Or higher | |
Storage capacity offered per node with SSD drives in TB (Hint :- Select '0' if not applicable) | 7.68 - 1000.0 Or higher | |
Storage Scalability per node with SSD drives in TB (Hint :- Select '0' if not applicable) | 0.0 - 8000.0 Or higher | |
Storage capacity offered per node with NL SAS drives in TB (Hint :- Select '0' if not applicable) | 0.0 - 1000.0 Or higher | |
Storage Scalability per node with NL SAS drives in TB (Hint :- Select '0' if not applicable) | 0.0 - 8000.0 Or higher | |
Storage capacity offered per node with NVMe in TB (Hint :- Select '0' if not applicable) | 0.0 - 1000.0 Or higher | |
Storage Scalability per node with NVMe in TB (Hint :- Select '0' if not applicable) | 0.0 - 8000.0 Or higher | |
RAM Capacity (Raw) offered per node in GB (Hint: Select 0 if not applicable) | 512.0 - 8192.0 Or higher | |
RAM scalability per node in GB | 768.0 - 8192.0 Or higher | |
No of cache drives per node | 0, 1, 2, 3, 4 | |
Cache offered per node in GB (Hint: Select '0' if not applicable) | 0.0 - 6400.0 Or higher | |
Cache scalability per node in GB (Hint: Select '0' if not applicable) | 0.0 - 12800.0 Or higher | |
Number of Network ports per node (Hint: Select '0' if not applicable | 4.0 - 10.0 Or higher | |
Throghput Per Network port | 10 Gbps | |
Type of Network port | Base T | |
HCI Interconnect Switches | Number of L2 Switches to be offered for Interconnection all the Network Ports in the Cluster | 2 |
Throughput Available per port | 10 Gbps, 25 Gbps, 40 Gbps, 100 Gbps, NA | |
Number of Available Ports for 10 Gbps throughput per Switch (Hint :- Select '0' if not applicable) | 48.0 - 100.0 Or higher | |
Number of Enabled Ports for 10 Gbps throughput per Switch (Hint :- Select '0' if not applicable) | 48.0 - 100.0 Or higher | |
Number of Available Ports for 25 Gbps throughput per Switch (Hint :- Select '0' if not applicable) | 4.0 - 100.0 Or higher | |
Number of Enabled Ports for 25 Gbps throughput per Switch (Hint :- Select '0' if not applicable) | 0.0 - 100.0 Or higher | |
Number of Available Ports for 40 Gbps throughput per Switch (Hint :- Select '0' if not applicable) | 0.0 - 100.0 Or higher | |
Number of Enabled Ports for 40 Gbps throughput per Switch (Hint :- Select '0' if not applicable) | 0.0 - 100.0 Or higher | |
Number of Available Ports for 100 Gbps throughput per Switch (Hint :- Select '0' if not applicable) | 2.0 - 100.0 Or higher | |
Number of Enabled Ports for 100 Gbps throughput per Switch (Hint :- Select '0' if not applicable) | 0.0 - 100.0 Or higher | |
PERFORMANCE | IOPS delivered at 70:30 Read:Write Ratio on 8K block size with latency of 5ms maximum for each node | 10000.0 - 100000.0 Or higher |
Scalability: Any additional node/ storage/ RAM added to the cluster to augment compute/storage/memory capacities, the same performance per node on upgraded node / Storage / RAM | Yes | |
ADDITIONAL PERFORMANCE PARAMETER | 1. NA | |
HCI FEATURES | HCI Features 1 | 1. HCI have all the features of offered industry standard hypervisor, 2. HCI have independently scale storage and compute as and when needed without any downtime., 3. HCI have mechanism for Metadata protection for all offered nodes within the cluster so as to provide high availability and no single point of failure., 4. HCI is configuration of SSD/SAS/NL SAS/NVMe then the caching must be on appropriate capacity of SSD/ NVME drives to meet the IOPS/performance requirements., 5. HCI supports thin provisioning of both storage entities and virtual machine hard disks, 6. HCI provides automatic failover in case of hardware failure., 7 VLAN for networking and integrated VM IP‟s Management capabilities, 8. HCI has security compliance methodology to ensure highly secure environment., 9. HCI has data replication with WAN optimization. |
HCI Features 2 | 1. HCI provides management through a remote/On premise GUI console. Also provides storage, compute & hypervisor metrics on a per VM /Node level as well as health and monitoring of entire platform., 2. Platform support LDAP Active Directory integration. The clients installed on any major Operating System., 3.Platform supports monitoring via SNMPv3 , email alerting via SMTP., 4. Capable of creating instant snapshots of virtual machines and maintaining multiple copies of snapshots & clones, 5. Capabability to support native VM/HCI level replication for installed Hypervisor | |
Supported industry protocols by HCI | 1.NFS, 2. SMB, 3. Iscsi | |
HCI capability to support File/Block Services and file/block replication across clusters for | 1. NFS, 2. CIFS, 3.SMB, 4. iSCSI | |
HCI Generic Parameters | Number of nodes HCI supports in same cluster/deployment, such that any node out of the offered be able to use the storage of all other nodes | 64.0 - 1000.0 Or higher |
"Hypervisor to be integrated with SDS" | outside kernel | |
HCI support | 1.AHV (Acropolis Hypervisor), 2. Hypervisor Agnostic Solution, 3. Hyper-V, 4.VSPHERE, 5. Xen Server, 6. KVM, 7. RHEV, 8.NA | |
"Bare-metal / Non Bare metal type of virtualization hypervisor" | Bare Metal | |
"Integration with Third Party FC Storage" | 6. NA | |
"The length of cable connecting the Nodes to the Switch (meters)" | 3.0 - 50.0 Or higher | |
Advance featrues of HCI | 1. NA | |
GENERIC PARAMETERS | The offered product have support from OEM for | 1. Updation for Patches and Bug fixes for software within supoort period., 2. Upgradation of version software within support period ., 3. Service and support from OEM within support period. |
Number of Years upto which support is available from OEM for Updation (Patches and Bug fixes) within support period | 5 | |
Number of Years upto which support is available from OEM for Upgradation of version within support period | 5 | |
"Number of years of service and support from OEM" | 5 | |
Installation, & Commissioning | Yes | |
Number of days Training Provided at Site by OEM | 0 | |