Catalogue values for Gas Chromatography

Category Specification Bid Requirement (Allowed Values)
GAS CHROMATOGRAPH (GC) CONFIGURATION "GC Detectors inclusive in the scope of supply (Select Only those Detectors, which are part of supply)" Flame Ionization Detector (FID)
"Number of FID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 2
"Number of TCD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0
"Number of ECD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0
"Number of NPD/FTD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0
"Number of FPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0
"Number of PID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0
"Number of PFPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" 0
Number of Inlets GC can Simultaneously Support 2
Number of Detectors (Ports) GC can Simultaneously Support 2
Number of Capillary Columns provided in GC - inclusive in the scope of Supply 1
Type of Capillary Column Non-Polar
"GC Capillary Column Length (Hint:-Select '0' if Not Applicable)" 30.0
"Number of Packed Columns provided in GC - inclusive in the scope of Supply (Hint:-Select '0' if Not Applicable)" 1
"GC Packed Column Length (Hint:-Select '0' if Not Applicable)" 6.0
PERFORMANCE "GC Detector Minimum Detection Level (MDL) " < 1.4 pg C/s for FID
COLUMN OVEN (GAS CHROMATOGRAPH - GC) Maximum Operating Temperature (GC Oven) upto 450 deg. C (2) Or higher
Number of Oven Ramps / Plateaus for Temperature programming 9/10 or more
Temperature Ramp Rate - Maximum 50 Deg. C/minute or better
PNEUMATIC CONTROL Number of Injection Ports 2
Maximum Injection Port heating Temperature upto 400 deg. C (1), upto 450 deg. C (2) Or higher
Pressure Range upto100 psi (1), upto 120 psi (2) Or higher
Pressure set point Resolution (±)(psi) 0.001, 0.01, 0.1 Or lower
Type of Sample Injection Port split / Splitless
Split Ratio 7500:1
AUTO INJECTOR / AUTO SAMPLER Compatible Liquid Auto Sampler - inclusive in the scope of supply No
Capacity of the Liquid Auto Sampler (Number of Vials) 0, 15, 100, 150 Or higher
Number of Injection Ports in the Liquid Auto Sampler 0
Number of Channels in the Liquid Auto Sampler 0
Minimum Volume of the injected liquid sample 0.0
Maximum Volume of the injected liquid sample 0.0
"Liquid Auto Sampler Features (Select applicable features Only)" NA
HEAD SPACE SAMPLER Compatible Head Space Sampler- inclusive in the scope of supply No
Capacity of the Head Space Sampler Carousel (number of Vials) NA
Head Space Sampler Temperature Range NA
PYROLYZER SYSTEM Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply No
SALIENT FEATURES OF GAS CHROMATOGRAPH (GC) "Salient Featutes of GC (Select applicable features Only)" Controlled by External PC System
SOFTWARE "Software Features (Select Applicable Features only)" Chromatographic attributes
GENERIC Display Built-in Display
Connectivity interface ETHERNET
Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously No
ACESSORIES Gas Supply inclusive in the scope of supply Not offered
Capacity of Gas cylinder Not offered
Number of Cyliners of each type supplied - inclusive in the scope of supply 0
Gas cylinders certified by PESO No for Gas Cylinder Not Offered
Regulator - inclusive in the scope of supply NA
"Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" Septa for injector x 100 nos
ENVIRONMENTAL Minimum Operating Temperature 0.0 - 10.0 Or lower
Maximum Operating Temperature 40.0 - 65.0 Or higher
Operating Humidity (RH) (%) at 40 degree C 95.0 - 95.0 Or higher
INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING Warranty on equipment 1.0
Number of days onsite training provided 3.0
CERTIFICATION / TEST REPORT "Availability of UL/CE Certificate as per IEC 61010- 1 latest - Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" Yes
Conformance to EMC/EMI as per IEC 61326-1 latest - Electrical equipment for measurement, control and laboratory use No
Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification No