Catalogue values for LED Luminaire (for Flood Light) as per IS 10322, IS 16107
Category | Specification | Bid Requirement (Allowed Values) |
---|---|---|
STANDARDS | LED Rating/System Wattage/Rated Power | 150W |
Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest | IP66 | |
Warranty for free replacement (in Years) | 2 | |
ELECTRICAL EFFICIENCY | Input operating Voltage range and frequency | 90 to 300 V olts AC at 50 Hz+/-2 Hz |
Rated voltage | 230 V AC 50 Hz | |
Total Harmonics Distortion (in %age) | ≤ 10 | |
OPTICAL | Colour temperature (+/-500K) | 5500K |
Working life for LED (Minimum 50,000 burning hours as per LM-80 report) | No, but with >/= 30000 Hours | |
Colour Rendering Index(CRI) | ≥70 | |
THERMAL MANAGEMENT | Heat sink should be die-cast aluminium along with sufficient heat sink fins to dissipate heat effectively | Yes |
Junction temperature | < 85 degC | |
Operating temperature range | -20 deg C to +50 deg C | |
PROTECTION | The luminaire shall be protected against surges and transients ( Internal) | >/=5KV |
The luminaire shall be protected against surges and transients of >/=10KV (External) | No | |
CONSTRUCTIONAL | Number of electronic control gear (power supplies) | 1 No. |
Length of ISI marked three core wire (shall be provided along with supply of material) | 50 cm | |
REPORTS AND CERTIFICATIONS | LED Make | OSRAM / NICHIA/CREE / SAMSUNG / SEOUL / LUMILED / PHILIPS / EDISON / SYSKA / LUMENMAX / EVERLIGHT / BRIDGELUX / NATIONSTAR / REFOND |