Catalogue values for Bipolar Diathermy Electrosurgical Unit (V2)
Category | Specification | Bid Requirement (Allowed Values) |
---|---|---|
GENERAL | Product Description | Bipolar Diathermy Electrosurgical Unit |
PRODUCT INFORMATION | Type | Monopolar & Bipolar output with easily visible display and easy to operate controls |
Control | Patient/Plate circuit monitoring, Output power monitoring, Self check control, H.F. Leakage currents control, Compensation of mains fluctuation | |
Maximum output power bipolar cut-coag BLEND | 90 W - 150 ohm | |
Maximum output power monopolar cut-coag BLEND | 250 W - 300 ohm | |
Maximum output power bipolar coag COAG | 70 W - 100 ohm | |
Maximum output power bipolar CUT | 95 W - 150 ohm | |
Maximum output power monopolar coag SPRAY | 120W | |
Maximum output power monopolar coag DEEP | 120 W - 200 ohm | |
Maximum output power monopolar cut ENHANCED | 250 W - 500 ohm | |
Maximum output power bipolar cut-coag CUT40% | 60 W - 150 ohm | |
Working frequency Monopolar / Bipolar (KiloHertz) | 500 | |
Maximum output power bipolar cut-coag CUT60% | 95 W - 150 ohm | |
Maximum output power bipolar cut-coag CUT80% | 95 W - 150 ohm | |
Maximum output power monopolar coag SPRAY ARGON | 70 W - 2000 ohm | |
Maximum output power monopolar cut-coag CUT40% | 200 W - 300 ohm | |
Maximum output power monopolar cut-coag CUT60% | 250 W - 300 ohm | |
Maximum output power monopolar cut-coag CUT80% | 350 W - 300 ohm | |
Maximum Output Power Monopolar Pure CUT | 400 W - 300 ohm | |
Maximum output power monopolar coag SPEEDY | 120 W - 500 ohm | |
Microprocessor or semi microprocessor control unit | Yes | |
Alarm and auto cut off in the events of poor contact or HF Leak | Yes | |
Accessories | Standard Accessories | Double water-proof foot-switch(1), Patient plate Re-Usable with cable adult(1), Patient plate Re-Usable with cable paediatric(1), Set of electrodes(Blade,Long Blade,needle & Ball)(1), Bipolar forceps straight blunt 15-16 cm(1), Bipolar forcep bayonet straight blunt 18-20 cm(1), Reusable bipolar cable 3 meter(1), Reusable handle with twin switches and cable(5), good quality trolley with castor wheel and multiple channel mounted drawers(1), Manual: GB, IT, Microsurgery needles 10 pieces, Microsurgery handle, Power supply cable 5 meter |
CERTIFICATIONS & REPORTS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
Availability of valid medical device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes | |
Manufacturing unit certification | ISO:13485 (Latest) | |
Availability of Test Report for each supplied batch/product as per Medical Device Rules (MDR) 2017 as amended till date | Yes | |
Compliance to Electrical Safety Standards | IEC/EN 60601-1 or Equivalent BIS Standard | |
Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement | Yes | |
WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 1.0 |
MISCELLANEOUS REQUIREMENTS | OEM/Reseller shall ensure uninterrupted availability of all spares for 10 years | Yes |
Availability of toll free facility for technical support maintened by OEM or authorized agencies | Yes | |
User/Technical/Maintenance manuals to be supplied in English in hard and soft copy | Yes | |
Details of equipments and procedures required for local calibration and routine maintenance to be supplied and advanced maintenance task documentation also to be furnished | Yes | |
List of important spares and accessories, with their part numbers to be supplied to the buyer at the time of supplying the equipment | Yes | |
Installation and Demonstration of equipment and training to be provided after completing supplies before acceptance | Yes | |
Principal Manufacturer must have direct Presence/approved service center In India | Yes | |